Data Centers & Technology

Data Centers & Technology

Data Center Engineering,
Built for Zero Downtime.

Team Systems designs, supplies, installs and supports the power, cooling, cabling, fire protection and monitoring systems behind data centers and technology facilities in Armenia — from enterprise server rooms to AI-scale infrastructure.

THE DATA CENTER CHALLENGE

Every Second of Downtime Has a Cost.

Data centers and server rooms carry the systems a business cannot run without. Power, cooling, connectivity and protection must work together — and keep working through maintenance, equipment failures and growth.

Team Systems engineers the critical infrastructure around the IT load as one coordinated system: from power distribution and precision cooling to structured cabling, fire suppression, physical security and continuous monitoring.

  • Redundant, fault-tolerant design
  • Power, cooling and IT planned together
  • Scalable from server room to data hall
  • Monitoring and support after handover

WHAT DATA CENTERS NEED

Four Priorities Behind Every Data Center Project.

Whether it is a new facility, a server room upgrade or a high-density AI deployment, operators ask the same four things of their critical infrastructure.

01

Continuous Uptime

Redundant power and cooling paths, so a single failure or a maintenance task never takes the IT load offline.

02

Energy Efficiency

Efficient UPS systems, aisle containment and cooling strategies that lower energy use and running costs as the load grows.

03

Physical & Fire Protection

Layered access control, video surveillance and clean-agent fire suppression that protect equipment without damaging it.

04

Room to Grow

Modular infrastructure that adds racks, power and cooling capacity in phases, without rebuilding the facility.

SYSTEMS WE INTEGRATE

Every System Behind the IT Load.

DESIGNED TOGETHER.
INSTALLED TOGETHER.
MONITORED TOGETHER.

Power Distribution & UPS

Switchboards, UPS systems, rack PDUs and generator integration, designed for redundant power paths to every rack.

  • UPS
  • PDU
  • Generator integration

Precision Cooling

Precision air conditioning and in-row cooling matched to rack density, with temperature and humidity kept within range.

  • Precision AC
  • In-row cooling
  • Humidity control

Structured Cabling & Fibre

High-density copper and fibre cabling, patching and cable management for racks, rows and links between buildings.

  • Fibre
  • Copper
  • Cable management

Racks & Containment

Server and network racks with hot and cold aisle containment, laid out for airflow, access and future expansion.

  • Racks
  • Aisle containment
  • Raised floor

Fire Detection & Suppression

Early-warning smoke detection and clean-agent gas suppression that put out a fire without harming the equipment.

  • Aspirating detection
  • Gas suppression
  • Fire alarm

Access Control & Security

Layered access from the site entrance to the server hall and individual racks, with every entry logged.

  • Biometric access
  • Rack-level access
  • Audit logs

CCTV & Video Surveillance

IP cameras covering the perimeter, entrances, corridors and server halls, with central recording and monitoring.

  • IP cameras
  • Recording
  • Monitoring

DCIM & Environmental Monitoring

Live monitoring of power, temperature, humidity, water leaks and equipment status, with alarms before problems reach the IT load.

  • DCIM
  • Sensors
  • Alerts

FROM GRID TO RACK

One Integrated Design for the Whole Facility.

ZONE 01

Power & Energy Room

Where the facility's energy begins — utility supply, generators and UPS systems that keep the IT load running through any outage.

INTEGRATED HERE

  • Switchboards & transfer switches
  • UPS systems & batteries
  • Generator integration
  • Power monitoring

ZONE 02

Server Hall

The racks, cabling and containment that house the IT load, arranged for airflow, easy access and growth.

INTEGRATED HERE

  • Server & network racks
  • Structured cabling & fibre
  • Hot & cold aisle containment
  • Rack power distribution

ZONE 03

Cooling Infrastructure

Precision cooling that removes heat at the rack and keeps temperature and humidity in range, every hour of the year.

INTEGRATED HERE

  • Precision air conditioning
  • In-row cooling
  • Temperature & humidity sensors
  • Water leak detection

ZONE 04

Network Operations Center

The control room where operators see every system at once — and respond before a problem ever reaches the IT load.

INTEGRATED HERE

  • DCIM software
  • Video wall & AV
  • Alarm management
  • CCTV monitoring

ZONE 05

Perimeter & Protection

Layered protection from the site fence to the server hall, so only the right people reach critical equipment — and fire never does.

INTEGRATED HERE

  • Perimeter intrusion detection
  • Perimeter CCTV
  • Access control & biometrics
  • Fire detection & gas suppression

HOW WE DELIVER

From First Assessment to Long-Term Support.

One team stays responsible from the first load assessment to monitoring after go-live, so nothing is lost between design, installation and operation.

  1. 01

    Consult

    Load, redundancy and growth requirements reviewed with your IT team.

  2. 02

    Design

    Coordinated power, cooling, cabling and safety design.

  3. 03

    Supply

    Equipment from our international manufacturer partners.

  4. 04

    Install

    Installation and phased migration, including in live facilities.

  5. 05

    Commission

    Integrated testing, failover tests and handover documents.

  6. 06

    Support

    Monitoring, maintenance and service for the life of the facility.

QUESTIONS

Data Center Systems: Frequently Asked Questions.

Can't find your answer? Our engineers are happy to review your data center or server room project.

Can you upgrade a server room without downtime?

Yes. We plan upgrades and migrations in phases, using temporary power and cooling where needed, so the IT load stays online throughout the work.

Which data center systems can Team Systems deliver?

Power distribution and UPS, precision cooling, structured cabling and fibre, racks and aisle containment, fire detection and gas suppression, access control, CCTV, and DCIM with environmental monitoring.

Can you support AI and high-density racks?

Yes. We plan power and cooling for high-density racks, including the containment and in-row cooling that AI and GPU equipment requires.

What redundancy level do you design for?

We design to the availability level your business requires — from N+1 for critical components to fully duplicated power and cooling paths — and document it for your review.

Do you provide monitoring and maintenance after handover?

Yes. After commissioning and failover testing, we provide monitoring, preventive maintenance and service so the facility keeps performing as it grows.

LET’S WORK TOGETHER

Planning a New Data Center or a Server Room Upgrade?

Tell us about your IT load, redundancy goals and growth plans. We will propose the right infrastructure — designed, installed and supported by one team.

UPTIME
SYSTEMS
ONE PARTNER
A STRONGER
TOMORROW.